<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Vagal Tone Archives - EMFSA</title>
	<atom:link href="https://www.emfsa.co.za/tag/vagal-tone/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.emfsa.co.za/tag/vagal-tone/</link>
	<description>Electromagnetic fields South Africa</description>
	<lastBuildDate>Wed, 27 Oct 2021 19:18:42 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://www.emfsa.co.za/wp-content/uploads/2021/02/cropped-EMFSA_logo-fv-32x32.png</url>
	<title>Vagal Tone Archives - EMFSA</title>
	<link>https://www.emfsa.co.za/tag/vagal-tone/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Electromagnetic fields in neonatal incubators: the reasons for an alert.</title>
		<link>https://www.emfsa.co.za/research-and-studies/electromagnetic-fields-in-neonatal-incubators-the-reasons-for-an-alert/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Tue, 05 Mar 2019 20:30:19 +0000</pubDate>
				<category><![CDATA[Research and Studies]]></category>
		<category><![CDATA[Babies]]></category>
		<category><![CDATA[EMF]]></category>
		<category><![CDATA[Incubators]]></category>
		<category><![CDATA[Magnetic Field]]></category>
		<category><![CDATA[Melatonin]]></category>
		<category><![CDATA[Neonatal]]></category>
		<category><![CDATA[Newborn]]></category>
		<category><![CDATA[Occupational Health]]></category>
		<category><![CDATA[PP]]></category>
		<category><![CDATA[Vagal Tone]]></category>
		<guid isPermaLink="false">https://www.emfsa.co.za/?p=7596</guid>

					<description><![CDATA[<p>https://doi.org/10.1080/14767058.2017.1390559 Abstract BACKGROUND: Neonatal incubators are important tools for sick newborns in the first few days of life. Nevertheless, their electric engine, often very close to the newborn&#8217;s body, emits electromagnetic fields (EMF) to which newborns are exposed. Aim of this paper is to review the available literature on EMF exposure in incubators, and the effects of [&#8230;]</p>
<p>The post <a href="https://www.emfsa.co.za/research-and-studies/electromagnetic-fields-in-neonatal-incubators-the-reasons-for-an-alert/">Electromagnetic fields in neonatal incubators: the reasons for an alert.</a> appeared first on <a href="https://www.emfsa.co.za">EMFSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>https://doi.org/10.1080/14767058.2017.1390559</p>
<p>Abstract</p>
<h6>BACKGROUND:</h6>
<p>Neonatal incubators are important tools for sick newborns in the first few days of life. Nevertheless, their electric engine, often very close to the newborn&#8217;s body, emits electromagnetic fields (<span class="highlight">EMF</span>) to which newborns are exposed. Aim of this paper is to review the available literature on <span class="highlight">EMF</span> exposure in incubators, and the effects of such exposures on newborns that have been investigated.</p>
<h6>METHODS:</h6>
<p>We carried out a systematic review of studies about <span class="highlight">EMF</span> emissions produced by incubators, using Medline and Embase databases from 1993 to 2017.</p>
<h6>RESULTS:</h6>
<p>We retrieved 15 papers that described the <span class="highlight">EMF</span> exposure in incubators and their biological effects on babies. <span class="highlight">EMF</span> levels in incubators appear to be between 2 and 100 mG, depending on the distance of the mattress from the electric engine. In some cases, they exceed this range. These values interfere with melatonin production or with vagal tone. Even caregivers are exposed to high <span class="highlight">EMF</span>, above 200 mG, when working at close contact with the incubators.</p>
<h6>CONCLUSION:</h6>
<p><span class="highlight">EMF</span> have been described as potentially hazardous for human health, and values reported in this review are an alert to prevent babies&#8217; and caregivers&#8217; exposure when close to the incubators. A precautionary approach should be adopted in future incubator design, to prevent high exposures of newborns in incubators and of caregivers as well.</p>
<p>(Image added by EMFSA)</p>
<p style="text-align: center;">
<p>The post <a href="https://www.emfsa.co.za/research-and-studies/electromagnetic-fields-in-neonatal-incubators-the-reasons-for-an-alert/">Electromagnetic fields in neonatal incubators: the reasons for an alert.</a> appeared first on <a href="https://www.emfsa.co.za">EMFSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
