<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Sweat duct Archives - EMFSA</title>
	<atom:link href="https://www.emfsa.co.za/tag/sweat-duct/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.emfsa.co.za/tag/sweat-duct/</link>
	<description>Electromagnetic fields South Africa</description>
	<lastBuildDate>Mon, 01 Nov 2021 11:42:58 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.4</generator>

<image>
	<url>https://www.emfsa.co.za/wp-content/uploads/2021/02/cropped-EMFSA_logo-fv-32x32.png</url>
	<title>Sweat duct Archives - EMFSA</title>
	<link>https://www.emfsa.co.za/tag/sweat-duct/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Frequency of the resonance of the human sweat duct in a normal mode of operation</title>
		<link>https://www.emfsa.co.za/research-and-studies/frequency-of-the-resonance-of-the-human-sweat-duct-in-a-normal-mode-of-operation/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Mon, 22 Oct 2018 05:48:25 +0000</pubDate>
				<category><![CDATA[Research and Studies]]></category>
		<category><![CDATA[5G]]></category>
		<category><![CDATA[Biomedical devices]]></category>
		<category><![CDATA[GHz]]></category>
		<category><![CDATA[Occupational Health]]></category>
		<category><![CDATA[Sweat duct]]></category>
		<category><![CDATA[THz]]></category>
		<category><![CDATA[Wireless Communicating Devices]]></category>
		<guid isPermaLink="false">http://www.emfsa.co.za/?p=6418</guid>

					<description><![CDATA[<p>Biomedical Optics Express Vol. 9, Issue 3, pp. 1301-1308 (2018) https://doi.org/10.1364/BOE.9.001301 Saroj R. Tripathi, Paul Ben Ishai, and Kodo Kawase Abstract The applications of terahertz (THz) waves have been increasing rapidly in different fields such as information and communication technology, homeland security and biomedical engineering. However, study on the possible health implications due to various [&#8230;]</p>
<p>The post <a href="https://www.emfsa.co.za/research-and-studies/frequency-of-the-resonance-of-the-human-sweat-duct-in-a-normal-mode-of-operation/">Frequency of the resonance of the human sweat duct in a normal mode of operation</a> appeared first on <a href="https://www.emfsa.co.za">EMFSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="row">
<div class="article-parents col-md-12">
<div class="row">
<ul class="small list-inline col-md-12 article-journal-name">
<li><strong>Biomedical Optics Express</strong></li>
<li>Vol. 9,</li>
<li>Issue 3,</li>
<li>pp. 1301-1308</li>
<li>(2018)</li>
<li class="article-doi"><a href="https://doi.org/10.1364/BOE.9.001301">https://doi.org/10.1364/BOE.9.001301</a></li>
</ul>
</div>
</div>
</div>
<p>Saroj R. Tripathi, Paul Ben Ishai, and Kodo Kawase</p>
<h5 id="Abstract" class="article-heading">Abstract</h5>
<p>The applications of terahertz (THz) waves have been increasing rapidly in different fields such as information and communication technology, homeland security and biomedical engineering. However, study on the possible health implications due to various biological effects induced by THz waves is relatively scarce. Previously, it has been reported that the human sweat ducts play a significant role in the interaction of the THz wave with human skin due to its coiled structure. This structure imposes on them the electromagnetic character of a helical antenna. To further understand these phenomena, we investigated the morphological features of human sweat ducts and the dielectric properties of their surrounding medium. Based upon these parameters, we estimated the frequency of the resonance of the human sweat duct in a normal mode of operation and our estimation showed that there is a broad resonance around 228 GHz. This result indicates that careful consideration should be given while designing electronic and photonic devices operating in the sub-terahertz frequency region in order to avoid various effects on human health due to these waves. <a href="https://www.osapublishing.org/boe/abstract.cfm?uri=boe-9-3-1301">https://www.osapublishing.org/boe/abstract.cfm?uri=boe-9-3-1301</a></p>
<p>Excerpts:</p>
<p>We estimated that the sweat duct in normal mode of operation resonates at 228 GHz and we believe that this finding will help to further investigate the various effects caused by high frequency electromagnetic wave in the sub-terahertz frequency band. Moreover, this result shows the important criteria to select high frequency electromagnetic wave for the development of biomedical devices and high-speed wireless communication system since the recent progress shows that the next generation communication systems such as THz wireless communication and body-centric nano-communications are expected to operate in a few hundreds of GHz. For example, research on high-speed THz communication systems is<br />
progressing rapidly utilizing the various frequency windows such as 140 GHz and 240 GHz due to the low atmospheric propagation loss. Besides this, extremely high-power sources of gyrotron operating in few hundreds of GHz are being studied for fusion experiments, where small stray radiation of such high power might become an important health issue for the workers in such environment.</p>
<p>Additional links added by EMFSA:</p>
<h6 class="ChapterTitle" lang="en">Terahertz Communications for 5G and Beyond <a href="https://link.springer.com/chapter/10.1007/978-3-319-63967-3_16">https://link.springer.com/chapter/10.1007/978-3-319-63967-3_16</a></h6>
<h6>5G won’t cope, terahertz will provide more bandwidth <a href="https://www.networkworld.com/article/3254184/mobile-wireless/5g-wont-cope-terahertz-will-provide-more-bandwidth.html">https://www.networkworld.com/article/3254184/mobile-wireless/5g-wont-cope-terahertz-will-provide-more-bandwidth.html</a></h6>
<blockquote class="wp-embedded-content" data-secret="6ov9xOVayz"><p><a href="https://www.siliconrepublic.com/comms/wireless-future-5g-terahertz-tssg-terapod-dell-emc">The wireless future beyond 5G is in the terahertz spectrum</a></p></blockquote>
<p><iframe class="wp-embedded-content" sandbox="allow-scripts" security="restricted"  title="&#8220;The wireless future beyond 5G is in the terahertz spectrum&#8221; &#8212; Silicon Republic" src="https://www.siliconrepublic.com/comms/wireless-future-5g-terahertz-tssg-terapod-dell-emc/embed/#?secret=6ov9xOVayz" data-secret="6ov9xOVayz" width="600" height="338" frameborder="0" marginwidth="0" marginheight="0" scrolling="no"></iframe></p>
<h6>TeraFemto: Terahertz Femtocell for 5G Mobile Networks <a href="https://nwcl.ku.edu.tr/thz.html">https://nwcl.ku.edu.tr/thz.html</a></h6>
<h6 class="title">Terahertz wireless could help cover the planet with internet that&#8217;s 10X faster than 5G <a href="https://www.techrepublic.com/article/terahertz-wireless-could-help-cover-the-planet-with-internet-thats-10x-faster-than-5g/">https://www.techrepublic.com/article/terahertz-wireless-could-help-cover-the-planet-with-internet-thats-10x-faster-than-5g/</a></h6>
<h6>Terahertz Technologies to Deliver OpticalNetwork Quality of Experience in WirelessSystems Beyond 5G</h6>
<p><a href="https://www.emfsa.co.za/wp-content/uploads/2018/10/1803.09060.pdf">1803.09060</a></p>
<p>The post <a href="https://www.emfsa.co.za/research-and-studies/frequency-of-the-resonance-of-the-human-sweat-duct-in-a-normal-mode-of-operation/">Frequency of the resonance of the human sweat duct in a normal mode of operation</a> appeared first on <a href="https://www.emfsa.co.za">EMFSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>The human skin as a sub-THz receiver &#8211; Does 5G pose a danger to it or not?</title>
		<link>https://www.emfsa.co.za/research-and-studies/human-skin-sub-thz-receiver-5g-pose-danger-not/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Fri, 04 May 2018 22:50:04 +0000</pubDate>
				<category><![CDATA[Research and Studies]]></category>
		<category><![CDATA[5G]]></category>
		<category><![CDATA[SAR]]></category>
		<category><![CDATA[Skin]]></category>
		<category><![CDATA[sub-THz]]></category>
		<category><![CDATA[Sweat duct]]></category>
		<guid isPermaLink="false">http://www.emfsa.co.za/?p=4876</guid>

					<description><![CDATA[<p>Betzalel N, Ben Ishai P, Feldman Y. The human skin as a sub-THz receiver &#8211; Does 5G pose a danger to it or not? Environ Res. 2018 May;163:208-216. doi: 10.1016/j.envres.2018.01.032. Epub 2018 Feb 22. PMID: 29459303. Abstract In the interaction of microwave radiation and human beings, the skin is traditionally considered as just an absorbing [&#8230;]</p>
<p>The post <a href="https://www.emfsa.co.za/research-and-studies/human-skin-sub-thz-receiver-5g-pose-danger-not/">The human skin as a sub-THz receiver &#8211; Does 5G pose a danger to it or not?</a> appeared first on <a href="https://www.emfsa.co.za">EMFSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Betzalel N, Ben Ishai P, Feldman Y. The human skin as a sub-THz receiver &#8211; Does 5G pose a danger to it or not? Environ Res. 2018 May;163:208-216. doi: 10.1016/j.envres.2018.01.032. Epub 2018 Feb 22. PMID: 29459303.</p>
<div class="abstr">
<h6>Abstract</h6>
<div class="">
<p>In the interaction of microwave radiation and human beings, the skin is traditionally considered as just an absorbing sponge stratum filled with water. In previous works, we showed that this view is flawed when we demonstrated that the coiled portion of the sweat duct in upper skin layer is regarded as a helical antenna in the sub-THz band.</p>
<p>Experimentally we showed that the reflectance of the human skin in the sub-THz region depends on the intensity of perspiration, i.e. sweat duct&#8217;s conductivity, and correlates with levels of human stress (physical, mental and emotional). Later on, we detected circular dichroism in the reflectance from the skin, a signature of the axial mode of a helical antenna.</p>
<p>The full ramifications of what these findings represent in the human condition are still unclear. We also revealed correlation of electrocardiography (ECG) parameters to the sub-THz reflection coefficient of human skin. In a recent work, we developed a unique simulation tool of human skin, taking into account the skin multi-layer structure together with the helical segment of the sweat duct embedded in it. The presence of the sweat duct led to a high specific absorption rate (SAR) of the skin in extremely high frequency band.</p>
<p>In this paper, we summarize the physical evidence for this phenomenon and consider its implication for the future exploitation of the electromagnetic spectrum by wireless communication. Starting from July 2016 the US Federal Communications Commission (FCC) has adopted new rules for wireless broadband operations above 24 GHz (5 G). This trend of exploitation is predicted to expand to higher frequencies in the sub-THz region.</p>
<p>One must consider the implications of human immersion in the electromagnetic noise, caused by devices working at the very same frequencies as those, to which the sweat duct (as a helical antenna) is most attuned. We are raising a warning flag against the unrestricted use of sub-THz technologies for communication, before the possible consequences for public health are explored.</p>
<p>Excerpt</p>
<p>The need for high data transmission rates, coupled with advances in semiconductor technology, is pushing the communications industry towards the sub-THz frequency spectrum. While the promises of a glorious future, resplendent with semi-infinite data streaming, may be attractive, there is a price to pay for such luxury. We shall find our cities, workspace and homes awash with 5 G base stations and we shall live though an unprecedented EM smog. The benefits to our society of becoming so wired cannot ignore possible health concerns, as yet unexplored. There is enough evidence to suggest that the combination of the helical sweat duct and wavelengths approaching the dimensions of skin layers could lead to non-thermal biological effects. Such fears should be investigated and these concerns should also effect the definition of standards for the application of 5G communications.</p>
</div>
</div>
<p>The post <a href="https://www.emfsa.co.za/research-and-studies/human-skin-sub-thz-receiver-5g-pose-danger-not/">The human skin as a sub-THz receiver &#8211; Does 5G pose a danger to it or not?</a> appeared first on <a href="https://www.emfsa.co.za">EMFSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
