<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Smartwatch Archives - EMFSA</title>
	<atom:link href="https://www.emfsa.co.za/tag/smartwatch/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.emfsa.co.za/tag/smartwatch/</link>
	<description>Electromagnetic fields South Africa</description>
	<lastBuildDate>Fri, 02 Oct 2020 21:50:24 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://www.emfsa.co.za/wp-content/uploads/2021/02/cropped-EMFSA_logo-fv-32x32.png</url>
	<title>Smartwatch Archives - EMFSA</title>
	<link>https://www.emfsa.co.za/tag/smartwatch/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Are Contemporary Smartwatches and Mobile Phones Safe for Patients With Cardiovascular Implantable Electronic Devices?</title>
		<link>https://www.emfsa.co.za/research-and-studies/are-contemporary-smartwatches-and-mobile-phones-safe-for-patients-with-cardiovascular-implantable-electronic-devices/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Fri, 02 Oct 2020 21:50:23 +0000</pubDate>
				<category><![CDATA[Research and Studies]]></category>
		<category><![CDATA[Electromagnetic Interference]]></category>
		<category><![CDATA[Implantable Electronic Device]]></category>
		<category><![CDATA[iPhone]]></category>
		<category><![CDATA[Mobile phone]]></category>
		<category><![CDATA[Smartwatch]]></category>
		<guid isPermaLink="false">https://www.emfsa.co.za/?p=16787</guid>

					<description><![CDATA[<p>Lacour P, Parwani AS, Schuessler F, Hohendanner F, Heinzel FR, Trippel TD, Boldt LH, Pieske B, Blaschke F. Are Contemporary Smartwatches and Mobile Phones Safe for Patients With Cardiovascular Implantable Electronic Devices? JACC Clin Electrophysiol. 2020 Sep;6(9):1158-1166. doi: 10.1016/j.jacep.2020.04.033. Epub 2020 Jul 29. PMID: 32972552. Abstract Objectives:&#160;Given the increasing prevalence of mobile phone and smartwatch [&#8230;]</p>
<p>The post <a href="https://www.emfsa.co.za/research-and-studies/are-contemporary-smartwatches-and-mobile-phones-safe-for-patients-with-cardiovascular-implantable-electronic-devices/">Are Contemporary Smartwatches and Mobile Phones Safe for Patients With Cardiovascular Implantable Electronic Devices?</a> appeared first on <a href="https://www.emfsa.co.za">EMFSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph" style="font-size:14px">Lacour P, Parwani AS, Schuessler F, Hohendanner F, Heinzel FR, Trippel TD, Boldt LH, Pieske B, Blaschke F. Are Contemporary Smartwatches and Mobile Phones Safe for Patients With Cardiovascular Implantable Electronic Devices? JACC Clin Electrophysiol. 2020 Sep;6(9):1158-1166. doi: 10.1016/j.jacep.2020.04.033. Epub 2020 Jul 29. PMID: 32972552.</p>



<p class="wp-block-paragraph" style="font-size:14px"><strong>Abstract</strong></p>



<p class="wp-block-paragraph" style="font-size:14px"><strong>Objectives:&nbsp;</strong>Given the increasing prevalence of mobile phone and smartwatch use, this study tested patients with cardiovascular implantable electronic devices (CIEDs) for the incidence and consequence of contemporary mobile phone and smartwatch-produced electromagnetic interferences.</p>



<p class="wp-block-paragraph" style="font-size:14px"><strong>Background:&nbsp;</strong>Electromagnetic interferences can be hazardous for patients with CIEDs.</p>



<p class="wp-block-paragraph" style="font-size:14px"><strong>Methods:&nbsp;</strong>In total, 148 patients with CIEDs and leads from 4 different manufacturers were subjected to 1,352 tests. Analyzed CIEDs included 51 pacemakers, 5 cardiac resynchronization therapy pacemakers, 46 implantable cardioverter-defibrillators, 43 cardiac resynchronization therapy defibrillators, and 3 implantable loop recorders. To analyze a possible influence of certain distances between the mobile phone (iPhone 6) and the smartwatch (Apple Watch A1553) to the CIED, both were placed either directly above implanted devices or at the right wrist. All possible activations of the iPhone and the Apple Watch, including the standby, dialing, and connecting modes (telephone connection and Internet access) were tested. In addition, we studied incidence and characteristics of interferences with interrogation telemetry.</p>



<p class="wp-block-paragraph" style="font-size:14px"><strong>Results:&nbsp;</strong>In this study, only a single case of mobile phone-induced electromagnetic interference on a dual-chamber pacemaker was observed. Utilizing wanded telemetry, iPhone induced interferences were found in 14% of the patients. However, none of the patients showed any interference with the Apple Watch.</p>



<p class="wp-block-paragraph" style="font-size:14px"><strong>Conclusions: </strong>The risk of electromagnetic interferences of the iPhone 6 and the Apple Watch with CIEDs is low. However, close proximity of the iPhone 6 to implanted devices can cause telemetry interferences.</p>



<p class="wp-block-paragraph" style="font-size:14px">Copyright © 2020 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.</p>
<p>The post <a href="https://www.emfsa.co.za/research-and-studies/are-contemporary-smartwatches-and-mobile-phones-safe-for-patients-with-cardiovascular-implantable-electronic-devices/">Are Contemporary Smartwatches and Mobile Phones Safe for Patients With Cardiovascular Implantable Electronic Devices?</a> appeared first on <a href="https://www.emfsa.co.za">EMFSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>The accuracy of blood pressure measurement by a smartwatch and a portable health device</title>
		<link>https://www.emfsa.co.za/research-and-studies/the-accuracy-of-blood-pressure-measurement-by-a-smartwatch-and-a-portable-health-device/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Tue, 20 Aug 2019 19:34:59 +0000</pubDate>
				<category><![CDATA[Research and Studies]]></category>
		<category><![CDATA[BodiMetrics Performance Monitor]]></category>
		<category><![CDATA[BP]]></category>
		<category><![CDATA[Smartwatch]]></category>
		<guid isPermaLink="false">https://www.emfsa.co.za/?p=9533</guid>

					<description><![CDATA[<p>https://www.tandfonline.com/doi/full/10.1080/21548331.2019.1656991 Abstract Handheld medical devices and smartwatches that measure BP without a cuff have recently become available. Since these measurements are relatively more user-friendly than conventional cuff-based measurements they may aid in more frequent BP monitoring. We investigated the accuracy and precision of two popular cuff-less devices: the Everlast smartwatch and the BodiMetrics Performance Monitor. [&#8230;]</p>
<p>The post <a href="https://www.emfsa.co.za/research-and-studies/the-accuracy-of-blood-pressure-measurement-by-a-smartwatch-and-a-portable-health-device/">The accuracy of blood pressure measurement by a smartwatch and a portable health device</a> appeared first on <a href="https://www.emfsa.co.za">EMFSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><a href="https://www.tandfonline.com/doi/full/10.1080/21548331.2019.1656991">https://www.tandfonline.com/doi/full/10.1080/21548331.2019.1656991</a></p>
<p>Abstract</p>
<p>Handheld medical devices and smartwatches that measure BP without a cuff have recently become available. Since these measurements are relatively more user-friendly than conventional cuff-based measurements they may aid in more frequent BP monitoring. We investigated the accuracy and precision of two popular cuff-less devices: the Everlast smartwatch and the BodiMetrics Performance Monitor.</p>
<p>Conclusions:</p>
<p>The Everlast smartwatch and the BodiMetrics Performance Monitor we tested are not accurate enough to be used as BP measurement devices.</p>
<p>The post <a href="https://www.emfsa.co.za/research-and-studies/the-accuracy-of-blood-pressure-measurement-by-a-smartwatch-and-a-portable-health-device/">The accuracy of blood pressure measurement by a smartwatch and a portable health device</a> appeared first on <a href="https://www.emfsa.co.za">EMFSA</a>.</p>