<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>ICNIRP Guidelines Archives - EMFSA</title>
	<atom:link href="https://www.emfsa.co.za/tag/icnirp-guidelines/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.emfsa.co.za/tag/icnirp-guidelines/</link>
	<description>Electromagnetic fields South Africa</description>
	<lastBuildDate>Mon, 13 Jul 2020 12:58:50 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://www.emfsa.co.za/wp-content/uploads/2021/02/cropped-EMFSA_logo-fv-32x32.png</url>
	<title>ICNIRP Guidelines Archives - EMFSA</title>
	<link>https://www.emfsa.co.za/tag/icnirp-guidelines/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Swiss expert group BERENIS: special newsletter on the ICNIRP guidelines</title>
		<link>https://www.emfsa.co.za/news/swiss-expert-group-berenis-special-newsletter-on-the-icnirp-guidelines/</link>
		
		<dc:creator><![CDATA[Editor]]></dc:creator>
		<pubDate>Mon, 13 Jul 2020 12:58:48 +0000</pubDate>
				<category><![CDATA[News]]></category>
		<category><![CDATA[5G]]></category>
		<category><![CDATA[ICNIRP]]></category>
		<category><![CDATA[ICNIRP Guidelines]]></category>
		<category><![CDATA[Knowledge Gaps]]></category>
		<category><![CDATA[Non thermal effects]]></category>
		<category><![CDATA[RFR-EMF]]></category>
		<category><![CDATA[Thermal]]></category>
		<guid isPermaLink="false">https://www.emfsa.co.za/?p=14750</guid>

					<description><![CDATA[<p>This special issue of the BERENIS newsletter contains a brief overview of the new guidelines of the International Commission on Non-Ionizing Radiation Protection (ICNIRP 2020), as well as a statement of the BERENIS expert group. New ICNIRP guidelines for radiofrequency electromagnetic fields (ICNIRP 2020). a) Derivation of the guidelines In March 2020, the International Commission [&#8230;]</p>
<p>The post <a href="https://www.emfsa.co.za/news/swiss-expert-group-berenis-special-newsletter-on-the-icnirp-guidelines/">Swiss expert group BERENIS: special newsletter on the ICNIRP guidelines</a> appeared first on <a href="https://www.emfsa.co.za">EMFSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<figure class="wp-block-image size-large"><img fetchpriority="high" decoding="async" width="783" height="114" src="https://www.emfsa.co.za/wp-content/uploads/2020/07/Berenis-ICNIRP-Guidelines.jpg" alt="" class="wp-image-14751" srcset="https://www.emfsa.co.za/wp-content/uploads/2020/07/Berenis-ICNIRP-Guidelines.jpg 783w, https://www.emfsa.co.za/wp-content/uploads/2020/07/Berenis-ICNIRP-Guidelines-300x44.jpg 300w, https://www.emfsa.co.za/wp-content/uploads/2020/07/Berenis-ICNIRP-Guidelines-768x112.jpg 768w" sizes="(max-width: 783px) 100vw, 783px" /></figure>



<p class="has-normal-font-size wp-block-paragraph">This special issue of the BERENIS newsletter contains a brief overview of the new guidelines of the International Commission on Non-Ionizing Radiation Protection (ICNIRP 2020), as well as a statement of the BERENIS expert group.</p>



<p class="has-normal-font-size wp-block-paragraph"><strong>New ICNIRP guidelines for radiofrequency electromagnetic fields (ICNIRP 2020).</strong></p>



<p class="has-normal-font-size wp-block-paragraph">a) <strong>Derivation of the guidelines</strong></p>



<p class="has-normal-font-size wp-block-paragraph">In March 2020, the International Commission on Non-Ionizing Radiation Protection (ICNIRP) has published new guidelines (ICNIRP 2020). These guidelines cover the RF EMF frequency range from 100 kHz to 300 GHz, replacing the corresponding sections of the 19981 and 20102 versions. In addition to currently used frequencies for 3G and 4G mobile phone, Wi-Fi and Bluetooth communication as well as DAB, the revised guidelines also cover the frequency range above 6 GHz, which will probably be used more intensively for mobile communications in the future.</p>



<p class="has-normal-font-size wp-block-paragraph">According to ICNIRP, the guidelines were developed on the basis of review reports on the topic, evaluations of individual studies, scientific workshops and an extensive public consultation process. For the development of the guidelines, ICNIRP considers effects being “harmful to human health and scientifically substantiated”.</p>



<p class="has-normal-font-size wp-block-paragraph">The identification of the “adverse health effect threshold” was based on the relevant literature on thermal and non-thermal effects on biological systems. According to ICNIRP, only thermal effects meet the criteria for sufficient evidence of adverse health effects, and therefore, the threshold values were based on thermal mechanisms. </p>



<p class="has-normal-font-size wp-block-paragraph">In order to account for uncertainty, additional reduction factors were applied to determine the restriction values. For whole-body exposure of e.g. mobile phone base stations, the proposed restriction value for the specific absorption rate (SAR) is 50 times lower than the threshold for human health effects assumed by ICNIRP. For local exposure from devices used close to the body, such as mobile phones, the reduction factor is 10. For occupationally exposed individuals, the reduction factors are 10 and 2 for whole-body exposure and local exposure, respectively.</p>



<p class="has-normal-font-size wp-block-paragraph">b) <strong>Comparison of the new and previous guidelines</strong></p>



<p class="has-normal-font-size wp-block-paragraph">The basic restrictions for whole-body exposure are still expressed as SAR and remain unchanged compared to the previous ICNIRP guidelines: 0.4 W/kg for occupational exposure and 0.08 W/kg for the general public. With regard to mobile communication frequencies, this corresponds to field strengths from 36 V/m (700 MHz) to 61 V/m (2 GHz). For frequencies of 2 GHz and above, the relevant measure is power flux density, which should not exceed 10 W/m².</p>



<p class="has-normal-font-size wp-block-paragraph">A modification in the new guidelines is that whole-body exposure is averaged over 30 minutes instead of 6 minutes, because new data show that steady-state conditions for whole-body exposure are reached after 30 minutes.</p>



<p class="has-normal-font-size wp-block-paragraph">Another modification is that occupational exposure of pregnant women should not exceed exposure of the general public to protect the foetus.</p>



<p class="has-normal-font-size wp-block-paragraph">For local exposure, the SAR per 10 g of tissue remains 2 W/kg for the head and torso and 4 W/kg for the limbs, or an absorbed power flux density of 20 W/m² at frequencies above 6 GHz (averaged over 6 minutes). </p>



<p class="has-normal-font-size wp-block-paragraph">In addition, more detailed specifications are given for local exposure with regard to short exposure durations of less than 6 minutes, and with regard to exposure of small body regions of a few square centimetres (averaged over 4 cm² from 6 GHz to 30 GHz, and 1 cm² above 30 GHz). </p>



<p class="has-normal-font-size wp-block-paragraph">These more precise specifications are important for the use of higher frequencies (above 6 GHz) to adequately protect the population.</p>



<p class="has-normal-font-size wp-block-paragraph">c) <strong>Statement of BERENIS</strong></p>



<p class="has-normal-font-size wp-block-paragraph">• In principle, the new guidelines do not change the level of protection of the population. </p>



<p class="has-normal-font-size wp-block-paragraph">The more precise guidelines for short-term and small-area exposures above 6 GHz should be considered by Swiss legislation before such frequencies are used for mobile communication in the future.</p>



<p class="has-normal-font-size wp-block-paragraph">• Although ICNIRP stated that there is no evidence for health effects below the RF-EMF exposure limit values, there are still some uncertainties in this respect. There is sufficient evidence that RFEMF exposure of the brain in the range of 1-2 W/kg has measurable effects on the brain’s electrical activity. </p>



<p class="has-normal-font-size wp-block-paragraph">• Furthermore, in cell and animal studies, relatively consistent effects on oxidative stress and on cellular signalling pathways have been found also below the limit values, while it is not clear whether these effects are associated with long-term health consequences. On the other hand, epidemiological research regarding long-term whole-body exposure above 1 V/m is insufficient.</p>



<p class="has-normal-font-size wp-block-paragraph">Emphasis added by EMFSA</p>



<figure class="wp-block-image size-large"><img decoding="async" width="732" height="225" src="https://www.emfsa.co.za/wp-content/uploads/2020/07/Berenis-PP-1.jpg" alt="" class="wp-image-14752" srcset="https://www.emfsa.co.za/wp-content/uploads/2020/07/Berenis-PP-1.jpg 732w, https://www.emfsa.co.za/wp-content/uploads/2020/07/Berenis-PP-1-300x92.jpg 300w" sizes="(max-width: 732px) 100vw, 732px" /></figure>



<figure class="wp-block-image size-large"><img decoding="async" width="733" height="208" src="https://www.emfsa.co.za/wp-content/uploads/2020/07/Berenis-PP-2.jpg" alt="" class="wp-image-14753" srcset="https://www.emfsa.co.za/wp-content/uploads/2020/07/Berenis-PP-2.jpg 733w, https://www.emfsa.co.za/wp-content/uploads/2020/07/Berenis-PP-2-300x85.jpg 300w" sizes="(max-width: 733px) 100vw, 733px" /></figure>



<p class="has-normal-font-size wp-block-paragraph"><strong>References</strong></p>



<p class="has-normal-font-size wp-block-paragraph">1. ICNIRP (1998): Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields<br>(up to 300 GHz). International Commission on Non-Ionizing Radiation Protection. Health Phys 74:494–521. </p>



<p class="has-normal-font-size wp-block-paragraph">2. ICNIRP (2010): Guidelines for limiting exposure to time-varying electric and magnetic fields (1 Hz to 100 kHz).<br>International Commission on Non-Ionizing Radiation Protection. Health Phys 99:818–836.</p>



<p class="has-normal-font-size wp-block-paragraph">3. Thielens A, Greco MK, Verloock L, Martens L, Joseph W (2020): Radio-Frequency Electromagnetic Field<br>Exposure of Western Honey Bees. Sci Rep. 2020;10(1):461.</p>



<p class="has-normal-font-size wp-block-paragraph">PDF <a href="https://www.emfsa.co.za/wp-content/uploads/2020/07/Newsletter_BERENIS-Special_Issue_July_2020-ENGLISH.pdf">https://www.emfsa.co.za/wp-content/uploads/2020/07/Newsletter_BERENIS-Special_Issue_July_2020-ENGLISH.pdf</a></p>



<p class="wp-block-paragraph"></p>



<p class="wp-block-paragraph"></p>
<p>The post <a href="https://www.emfsa.co.za/news/swiss-expert-group-berenis-special-newsletter-on-the-icnirp-guidelines/">Swiss expert group BERENIS: special newsletter on the ICNIRP guidelines</a> appeared first on <a href="https://www.emfsa.co.za">EMFSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
